1.壓型鋼板腹板與翼緣水平面之間的夾角戶不宜小于45度。這在生產(chǎn)板型時(shí)應(yīng)考慮的。
The included angle between the profiled steel plate web and the flange horizontal plane should not be less than 45 degrees. This should be considered when producing plate shapes.
2.壓型鋼板好采用鍍鋅鋼板、鍍鋁鋅鋼板或在其基材上涂有彩色有機(jī)涂層的鋼板輥壓成型的三種防銹觸方法。
The profiled steel plate can be rolled using three rust prevention methods: galvanized steel plate, aluminum zinc plated steel plate, or steel plate coated with color organic coating on its substrate.
3.
濟(jì)南彩鋼廠家提醒,鋼結(jié)構(gòu)房屋屋面、墻面壓型鋼板的基材厚度宜取0.4一1.6mm,,一般采用0.6-1.0mm壓型鋼板宜采用長尺板材,以減少板長度方向之搭接。
Jinan Color Steel Factory reminds that the base material thickness of profiled steel plates for roofs and walls of steel structure buildings should be 0.4-1.6 mm, and generally 0.6-1.0 mm profiled steel plates should be long gauge plates to reduce overlap in the length direction of the plates.
4.壓型鋼板長方向的搭接必須與支承構(gòu)件(如檁條、墻梁等)有緊固的連接,搭接部位應(yīng)設(shè)置防水密封膠帶(避免腐蝕),搭接長度不宜小于下列限值:
The overlap of the profiled steel plate in the long direction must have a tight connection with the supporting components (such as purlins, wall beams, etc.). The overlap part should be provided with waterproof sealing tape (to avoid corrosion), and the overlap length should not be less than the following limits:
1)波高≥70mm的高波屋面壓型鋼板350mm
1) High wave roof profiled steel plate with wave height ≥ 70mm 350mm
2)波高<70mm的中低波屋面壓型鋼板,屋面坡度≤1/10時(shí)250mm
2) Medium and low wave roof profiled steel plate with wave height<70mm, 250mm when roof slope ≤ 1/10
3)屋面坡度>1/10時(shí)200mm
3) 200mm when roof slope > 1/10
4)墻面壓型鋼板:120mm
4) Wall profiled steel plate: 120mm
5.屋面壓型鋼板側(cè)向可采用搭接式、扣合式和咬合式等連接方式。當(dāng)側(cè)間采用搭接式連接時(shí),一般搭接一波,當(dāng)有特殊要求的時(shí)候可搭接兩波。搭接處用連接件緊固,連接件應(yīng)設(shè)置在波峰上,連接件應(yīng)采用帶有防水密封膠墊的自攻螺拴。對(duì)于高波壓型鋼板,連接件間距一般為700-800mm,;對(duì)于中低波壓型鋼板,連接件間距一般為300-400mm。
5. The roof profiled steel plate can be connected laterally by lap, snap, and snap connections. When lap joint connection is used between the sides, generally one wave of lap joint can be used, and when there are special requirements, two waves can be used. The overlap shall be fastened with connectors, which shall be set on the wave crest. The connectors shall be self tapping bolts with waterproof sealant pads. For high wave profiled steel plates, the spacing between connectors is generally 700-800mm,; For medium and low wave profiled steel plates, the spacing between connectors is generally 300-400mm.
當(dāng)側(cè)向采用扣合式或咬合式連接時(shí),應(yīng)在檁條上設(shè)置與壓型鋼板波形相配套的專門固定支座,固定支座與檁條用自攻螺釘或射釘連接,壓型鋼板擱置在固定支座上,兩片壓型鋼板的側(cè)邊應(yīng)確保在風(fēng)吸力等因素作用下的扣合或咬合連接可靠。
When using a snap or snap connection on the lateral side, a special fixed support that matches the waveform of the profiled steel plate should be provided on the purlin. The fixed support should be connected to the purlin using self-tapping screws or shooting screws. The profiled steel plate should be placed on the fixed support. The side edges of the two profiled steel plates should ensure reliable snap or snap connection under the action of wind suction and other factors.
6.墻面壓型鋼板之間的側(cè)向連接宜采用搭接連接,通常搭接一個(gè)波峰,板與板的連接件可設(shè)在波峰,亦可設(shè)在波谷。連接件宜采用帶有防水密封膠墊的自攻螺釘。
The lateral connection between wall profiled steel plates should be connected by overlapping, usually overlapping a wave peak. The connection between plates can be set at the wave peak or at the wave valley. The connection should use self-tapping screws with waterproof sealant pads.
7.鋪設(shè)高波壓型鋼板屋面時(shí),應(yīng)在檁條下設(shè)置固定支架,檁條上翼緣寬度應(yīng)比固定支架寬度大10mm,固定支架用自攻螺燈或射釘與檁條連接,每波設(shè)置一個(gè)。低波壓型鋼板可不設(shè)固定支架,宜在波峰處采用帶有防水密封膠墊的自攻螺釘或射釘與檁條連接,連接件可每波或隔波設(shè)置個(gè),但每塊低波壓型鋼板不得小于3個(gè)連接件。
When laying a high wave profiled steel sheet roof, a fixed bracket should be set under the purlin, and the width of the upper flange of the purlin should be 10mm larger than the width of the fixed bracket. The fixed bracket should be connected to the purlin using a self-tapping screw lamp or a stud, and one should be set for each wave. The low wave pressure profiled steel plate may not be provided with a fixed bracket. It is advisable to use self-tapping screws or rivets with waterproof sealant pads at the wave crest to connect to the purlin. The connectors may be set per wave or wave isolation, but each low wave pressure profiled steel plate shall not be less than 3 connectors.
壓型鋼板可以單獨(dú)使用,用于不保溫建筑的外墻、屋面或裝飾,也可以與巖棉或玻璃棉組合成各種保溫屋面及墻面。它具有質(zhì)輕、高強(qiáng)色澤豐富、施工方便快捷、抗震防火、防雨、壽命長、免維修等特點(diǎn),現(xiàn)已被逐漸推廣應(yīng)用。您有需求就來聯(lián)系我們
http://吧!
Profiled steel sheets can be used alone for exterior walls, roofs, or decoration of non thermal insulation buildings, or can be combined with rock wool or glass wool to form various thermal insulation roofs and walls. It has the characteristics of light weight, high strength, rich color, convenient and fast construction, earthquake resistance, fire prevention, rain prevention, long service life, and maintenance free, and has been gradually promoted and applied. Please contact us if you have any needs http:// Come on!